4-10
4.12.3 Printout too light
Symptom: Printed image is faint or does not print solid.
Poor development
•
Remove the toner cartridge and shake it a few times to redistribute the
toner inside. If the problem persists, replace the toner cartridge.
•
Replace the High Voltage Unit.
•
Clean the LED print head.
Defective Drum
•
Replace the Drum Cartridge.
Poor image transfer
•
Replace the Image Transfer Unit.
•
Replace the High Voltage Unit.
•
Replace the Main Control PCB.
4.12.4 Printout too dark
Symptom: Printed image is faint or does not print solid.
Poor development
•
Remove the toner cartridge and shake it a few times to redistribute the
toner inside. If the problem persists, replace the toner cartridge.
•
Replace the High Voltage Unit.
•
Clean the LED print head.
Defective Drum
•
Replace the Drum Cartridge.
Poor image transfer
•
Replace the Image Transfer Unit.
•
Replace the High Voltage Unit.
•
Replace the Main Control PCB.
4.12.5 Blurred background
Symptom: Copies show a grey or dark background.
Poor development
•
Replace the High Voltage Unit.
•
Replace the Main Control PCB.
•
Replace the Toner Cartridge.
•
Replace the Drum Cartridge.
Содержание OKIOFFICE 120
Страница 7: ...vi ...
Страница 17: ...1 10 1 7 Dimensions Dimension in mm ...
Страница 23: ...1 16 1 11 ID Label Specification 1 12 Labels location ...
Страница 24: ...2 1 Section2 Machine Composition 2 1 Interconnect Block Diagram ...
Страница 25: ...2 2 ...
Страница 87: ...3 46 Unique Switch F 7 and F 9 Factory use only ...
Страница 190: ...5 60 Note If you re attach the feed roller B put the right and left nibs into the fixing hole as shown ...
Страница 195: ...5 65 10 Move the cassette PCB by sliding it 11 Disconnect the all connectors on the cassette PCB ...