
3-29
3.5 All RAM Clear
The All RAM Clear setting will erase all user programmed information, all documents in memory, and
reset the memory switches and machine parameters to factory defaults.
This feature may also be used to try and clear a machine malfunction or lock up. If possible, when the
All RAM Clear is used to reset a malfunction or lock up, it is advisable to print the machine settings,
one-touch and speed dial listings to help in reprogramming this information.
1. To perform an All RAM Clear, from standby, press PROGRAM, *, 3.
All RAM Clear
Check Program/Enter
2. Press ENTER.
Note: To finish the operation without performing RAM clear, press STOP or PROGRAM.
Note: This setting does not clear the life monitor and the consumable order sheet data.
3.6 Setting Individual Autodialer Attributes
This function allows the user to configure an individual one-touch or speed dial entry with the settings
shown in Memory Switches B:0, B:1, B:2 and B:3.
To set the individual attributes:
1. Change memory switch B:5, bit 7 to a “1”. (See setting 3.3.1 Setting the Memory Switches for more
information on changing memory switch B:5.)
2. When the function is enabled, an “Attribute” option is added to the autodialer programming steps.
As a one-touch or speed dial location is programmed, an extra step showing Attribute 1, Attribute
2, Attribute 3, and Attribute 4 are added as the last step.
A :Attribute1
10001101
Bit No. 76543210
3. Set the individual bit positions as shown in the following table. To change a setting, press
or
until the cursor is the below the desired bit position; then press “1” or “0” to make the change.
Содержание OKIOFFICE 120
Страница 7: ...vi ...
Страница 17: ...1 10 1 7 Dimensions Dimension in mm ...
Страница 23: ...1 16 1 11 ID Label Specification 1 12 Labels location ...
Страница 24: ...2 1 Section2 Machine Composition 2 1 Interconnect Block Diagram ...
Страница 25: ...2 2 ...
Страница 87: ...3 46 Unique Switch F 7 and F 9 Factory use only ...
Страница 190: ...5 60 Note If you re attach the feed roller B put the right and left nibs into the fixing hole as shown ...
Страница 195: ...5 65 10 Move the cassette PCB by sliding it 11 Disconnect the all connectors on the cassette PCB ...