3-30
Attribute 1 - Individual Autodialer Setting
(Equivalent to Memory Switch B:0)
Switch
Initial
Setting
Adjust
Usage/Comments
7
1
Busy tone detection
0: No
1: Yes
Sets this switch to “0” if the ring tone of remote unit
is mistaken for a busy signal.
6
0
Fallback pattern (bps)
2400 4800 7200 9600 14400
Set at 0: 2 times 2 times 2 times 2 times 2 times
Set at 1: 4 times 1 times 1 times 1 times 1 times
5
0
Overseas mode
0: No
1: Yes
Re-enables echo suppression that is disabled by
the CED signal (2100 Hz). Also ignores the first DIS
signal and transmits the DCS signal in response to
the second DIS signal.
4
0
V.29 Echo Protect tone
0: No
1: Yes
International telephone lines equipped with echo
suppression will cut the beginning portion of the
transmitted information which may cause the
receiver not to receive the training and data. To
protect the received image from degrading, a 0.5
second Echo Protect tone is placed prior to the
training using G3 high speed modem training
(V.29).
3
1
Maximum transmit speed (kbps)
2.4 4.8 7.2 9.6 12 14.4 16.8 19.2 21.6 24 26.4 28.8 31.2 33.6
2
1
0 0 0 0 0 0 0 0 1 1 1 1 1 1
0 0 0 0 1 1 1 1 0 0 0 0 1 1
1
0
0 0 1 1 0 0 1 1 0 0 1 1 0 0
0 1 0 1 0 1 0 1 0 1 0 1 0 1
0
1
Note: It is maximum 33.6 kbps only when AL-100 optional module is attached to OKIOFFICE
120 model. Standard OKIOFFICE 120 model is maximum 14.4 kbps.
Attribute 2 - Individual Autodialer Setting
(Equivalent to Memory Switch B:1)
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
The time between reception of CFR and transmission of data
When CFR and data overlap due to line echo, increase the interval between CFR
and data transmission using this switch.
6
1
250 ms 500 ms 750 ms 1000 ms
Switch 7 0 0 1 1
Switch 6 0 1 0 1
5
0
Interval between DCS and TCF
When FTT is received after DCS and TCF signals due to line echo, increase the
interval between DCS and TCF signals using this switch.
4
0
75 ms 300 ms 450 ms 600 ms
Switch 5 0 0 1 1
Switch 4 0 1 0 1
3
1
2
0
Output attenuation
See table on next page
1
0
0
1
Содержание OKIOFFICE 120
Страница 7: ...vi ...
Страница 17: ...1 10 1 7 Dimensions Dimension in mm ...
Страница 23: ...1 16 1 11 ID Label Specification 1 12 Labels location ...
Страница 24: ...2 1 Section2 Machine Composition 2 1 Interconnect Block Diagram ...
Страница 25: ...2 2 ...
Страница 87: ...3 46 Unique Switch F 7 and F 9 Factory use only ...
Страница 190: ...5 60 Note If you re attach the feed roller B put the right and left nibs into the fixing hole as shown ...
Страница 195: ...5 65 10 Move the cassette PCB by sliding it 11 Disconnect the all connectors on the cassette PCB ...