Procedure 13: Setup communication port
1. From
230 COMM PORT SETUP
screen, press SELECT to move to one of the
following baud rates:
•
9600 (default)
•
1200
•
4800
•
300
•
2400
•
19200
Press ENTER to select
2 Screen
231 COMM PORT SETUP
displays the prompt, “HOW MANY DATA
BITS?”
Select either of the following:
•
8-bits (default)
•
7-bits
Press ENTER
3. Screen
232 COMM PORT SETUP
displays the prompt, “SELECT PARITY.”
Select one of the following:
•
NONE (default)
•
ODD
•
EVEN
Press ENTER
4 Screen
233 COMM PORT SETUP
displays, “HOW MANY STOP BITS?”
Select from either of the following:
•
2-BITS
•
1-BIT (default)
Press ENTER
5.
Connect the write protect jumper JP17
6. Screen
234 COMM PORT SETUP
displays, “SAVE IN EEPROM?”
Select
YES
or
NO
and press ENTER
7.
Disconnect the write protect jumper, JP17. This protects the information in the
EEPROM.
Содержание W-4510
Страница 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 36: ...Installation W 4510 Weigh Scale Technical Reference Manual 19 Figure 6 Typical Smart Pro dimensions...
Страница 48: ...Installation W 4510 Weigh Scale Technical Reference Manual 31 Figure 13 W 4510 terminal illustration...
Страница 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...