Setup
W-4510 Weigh Scale Technical Reference Manual
51
Table 13: Smart Pro CPU board test point information
TP# Section
Reference
TP1
Analog output#1
Voltage signal
TP2 AC/DC
power
+5VDC
TP3
AC/DC power
+5VDC common
TP4 AC/DC
power
–15VDC
TP5 AC/DC
power
+15VDC
TP6
AC/DC power
15VDC common
TP7
Analog output #2
Voltage signal
TP8
Analog output #2
Voltage signal
Procedure 7: Select output type
1. From
the
063 SELECT OUTPUT TYPE
, select either of the following options;
•
4–20 or 0–20 Channel #1
•
4–20 or 0–20 Channel #2
Press ENTER
Note: If you require a voltage output, choose 0–20 on screen 63 and connect a
jumper for Channel #1 to JP1 and Channel #2 to JP2
2.
Connect the write protect jumper JP17
3.
Save to EEPROM
4.
Disconnect the write protect jumper, JP17. This protects the information in the
EEPROM.
Содержание W-4510
Страница 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 36: ...Installation W 4510 Weigh Scale Technical Reference Manual 19 Figure 6 Typical Smart Pro dimensions...
Страница 48: ...Installation W 4510 Weigh Scale Technical Reference Manual 31 Figure 13 W 4510 terminal illustration...
Страница 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...