Calibration
102
W-4510 Weigh Scale Technical Reference Manual
Procedure 35: Collect data for span Channel#2—high process
1. From
the
MAIN MENU 1 OF 2
screen, press SELECT to choose
CALIBRATE
SYSTEM
and press ENTER
2. From
018 CAL MENU 1 OF 2
screen, press SELECT to choose
CALIBRATE
GAGE
and press ENTER
3. From
008 CALIBRATE GAGE
screen, press ENTER at
SELECT CHANNEL
Note: Verify that you are using the correct product code (0-8 for Channel #1 or 9
for Channel #2)
4. From
146 CAL CHANNELS
screen, select
CAL CHANNEL #2
and press ENTER
5A. From
185
CAL CHANNEL #2
screen, press SELECT to choose
CAL HI ON
PROCESS
and press ENTER
5B.
Turn off the source, load belt statically, and turn on source. Try to replicate the
loading profile
6. From
200 CALIBRATE HI ON PROCESS
screen, press SELECT to choose either
YES
or
NO
7. From
201
CAL TIME LEFT AFTER TIMEOUT
, press ENTER when the countdown
reaches 0 seconds left
Note: Stop the conveyor at this point and collect a known length of the material.
Weigh the material and determine the lbs/ft
8. From
202 ENTER PROD VAL
screen, enter the actual value of the process and
press ENTER. Screen
156
displays again with the cursor on the
YES
line. Press
ENTER to continue
9. On
the
157
SAVE CALIBRATE RESULT IN UPPER RAM?
screen, press ENTER
on the
YES
line to save to upper RAM or
NO
to abort the save
10.
If you choose to save the results, the AVG. COUNT stores in memory for later use.
11.
Press SELECT to choose the
YES
and press ENTER to continue
12.
Connect the write protect jumper, JP17 and save to EEPROM
13.
Disconnect the write protect jumper, JP17.
Содержание W-4510
Страница 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 36: ...Installation W 4510 Weigh Scale Technical Reference Manual 19 Figure 6 Typical Smart Pro dimensions...
Страница 48: ...Installation W 4510 Weigh Scale Technical Reference Manual 31 Figure 13 W 4510 terminal illustration...
Страница 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...