Appendix I: Parameter blocks
W-4510 Weigh Scale Technical Reference Manual
131
Table 15: Screen 520 OR 521 Frequency input block (continued)
Item#
Parameter Name
Parameter Description
32
LOW SAMPLE INPUT
Enter actual value of Low Process sample collected for Standardize and
Calibrate Low procedures
33
HIGH SAMPLE INPUT
Enter actual value of High Process sample collected for Calibrate High a
procedure
34
LOW OUTPUT
Indicates time remaining during Low data collection and shows Cal. Check
value when data collection complete
35
HIGH OUTPUT
Indicates time remaining during High data collection and shows Cal. Check
value when data collection complete
36
DURATION TYPE
Enter 1=timed, 2=Start/Stop, 3=tach pulses, 4=tach/10, and 5=tach/100
37
DURATION
Enter 1 to 65535 seconds, tach pulses, tach pulses/10, or tach pulses/100.
No entry needed for STDZ
38
CALIBRATE LOW
DATE
Date that current standardize or calibrate low was performed
39
STDZ/CAL. LOW
AVERAGE COUNTS
Raw count average from data collection during most recent Standardize or
Cal. Low procedure
40
CAL. HIGH AVERAGE
COUNTS
Raw count average from data collection during most recent Calibrate High
procedure
41
ALARM LIMIT
Enter 0 to 65535% of change from last standardize that should cause an
alarm. Enter 0 to turn off alarm function
42
TOTALIZER
Accumulated total weight over the duration of the most recent Cal. High
data collection. Use for Cal High on bulk total
43
TOTALIZER SCALING
Converts Rate data to a total. Rate divides by this factor before adding into
total
44
STDZ HISTORY #1
DATE
Date of Stdz. or Cal Low before current
45
STDZ HISTORY #1
COUNTS
Standardize counts for that date
46
STDZ HISTORY #2
DATE
Date of Stdz. or Cal Low before History 1
47
STDZ HISTORY #2
COUNTS
Standardize counts for that date
48
STDZ HISTORY #3
DATE
Date of Stdz. or Cal Low before History 2
49
STDZ HISTORY #3
COUNTS
Standardize counts for that date
Содержание W-4510
Страница 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 36: ...Installation W 4510 Weigh Scale Technical Reference Manual 19 Figure 6 Typical Smart Pro dimensions...
Страница 48: ...Installation W 4510 Weigh Scale Technical Reference Manual 31 Figure 13 W 4510 terminal illustration...
Страница 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...