background image

 

1

 
 
 
 
 

Floor Hugger 

Low-Profile Electronic 

Platform Scale 

Owner’s Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

CARDINAL SCALE MFG. CO. 

1905-M142-O1 Rev D 

203 E. Daugherty, Webb City, MO 64870 USA

05/01 

Ph: 417-673-4631 

Fax: 417-673-2153

Printed in USA

 www.cardinalscale.com 

 

Technical Support: Ph: 866-254-8261 

 [email protected] 

Содержание Floor Hugger

Страница 1: ...c Platform Scale Owner s Manual CARDINAL SCALE MFG CO 1905 M142 O1 Rev D 203 E Daugherty Webb City MO 64870 USA 05 01 Ph 417 673 4631 Fax 417 673 2153 Printed in USA www cardinalscale com Technical Support Ph 866 254 8261 tech cardet com ...

Страница 2: ...2 ...

Страница 3: ...ability is assumed with respect to the use of the information contained herein TABLE OF CONTENTS Introduction 1 Installation 2 Calibration Procedure 3 Trim Adjustment 4 Trouble Shooting Guide 5 Interconnection Diagram 6 FCC COMPLIANCE STATEMENT This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions in this manual may c...

Страница 4: ...al Scale should remain packed until you are ready to install it protecting it while being stored Remove shipping bands and packing material Make certain all packing material is removed Remove wooden box containing load cell cable from pallet Place on scale platform until further instructions are given BE CERTAIN scale location is level and free of debris Using the lifting eye bolt provided move sc...

Страница 5: ...able to weight indicating instrument following instructions provided in instrument manual Make certain cable is not placed near heating or cooling ducts relay panels ovens or other types of electrical equipment All cables should be routed out of the way of normal traffic and secured to prevent accidental damage to operator and or instruments After connection has been made power up and zero weight ...

Страница 6: ...t weight on the corner with the highest reading and adjust the appropriate trim potentiometer until the weight reading agrees with the lowest reading obtained in Step 5 7 Repeat Step 6 until all corners have the same weight reading 8 Replace screws securing the junction box cover and access plate Figure No 3 If two or more load cells must be replaced or scale needs an over all resealing of each co...

Страница 7: ... SOLUTION Scale reads accurate weight to a point but will not register beyond that point Obstruction between floor and bridge Remove obstruction Cannot obtain repeatable readings A Scale not level B Bad or improper wiring C Bad load cell D Bad trim circuit board A Level Scale B Check wiring solder connections C Replace load cell D Replace trim circuit board One corner will not register correct wei...

Страница 8: ...6 INTERCONNECTION DIAGRAM Figure No 4 ...

Страница 9: ...7 ...

Страница 10: ...8 ...