
Appendix I: Parameter blocks
132
W-4510 Weigh Scale Technical Reference Manual
Screen 522 Frequency Output Block
522 FREQOT CHANNEL
ITEM 000 NEXT=000
CURRENT VAL
NEW VAL
000000
000000
Figure 66: Frequency output channel screen
The base address for screen 522 FREQOT CHANNEL is 529, item 1024.
Table 26: Screen 522 Frequency Output block Channel #1
Item#
Parameter Name
Parameter description
0
STATUS
Enter an even number to turn on block. Enter an odd number to turn off block.
Enter 10 to force block to use internal limits rather than Product Code table
limits
1
COUNTER
INITIALIZE
Equals 1 if counter that connects to this block was previously initialized. Power
loss may require re-initialization of counters. Enter 0 to re-initialize and the
computer changes to 1
2
SPARE
3
DATA POINTER
Pointer to address of output data location
4
LOW LIMIT
Value of data from the data pointer that gives minimum analog output—4mA or
0V
5
HIGH LIMIT
Value of data from data pointer that gives maximum analog output—20mA or
10V
6
OUTPUT COUNTS
Count value actually sent to counter. See description below
7
RANGE SELECT
Enter 0 to select 4–20mA range. Enter 1 to select 0–20mA range. Use screen
#63 to setup
Table 27: Screen 522 Frequency Output block Channel #2
Item#
Parameter Name
Parameter description
8
STATUS
Enter an even number to turn on block. Enter an odd number to turn off block.
Enter 10 to force block to use internal limits rather than Product Code table
limits
9
COUNTER
INITIALIZE
Equals 1 if counter that connects to this block was previously initialized. Power
loss may require re-initialization of counters. Enter 0 to re-initialize and the
computer changes to 1
10
SPARE
11
DATA POINTER
Pointer to address of output data location
12
LOW LIMIT
Value of data from the data pointer that gives minimum analog output—4mA or
0V
13
HIGH LIMIT
Value of data from data pointer that gives maximum analog output—20mA or
10V
14
OUTPUT COUNTS
Count value actually sent to counter. See description below
15
RANGE SELECT
Enter 0 to select 4–20mA range. Enter 1 to select 0–20mA range. Use screen
#63 to setup
Содержание W-4510
Страница 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 36: ...Installation W 4510 Weigh Scale Technical Reference Manual 19 Figure 6 Typical Smart Pro dimensions...
Страница 48: ...Installation W 4510 Weigh Scale Technical Reference Manual 31 Figure 13 W 4510 terminal illustration...
Страница 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...