Setup
W-4510 Weigh Scale Technical Reference Manual
57
Procedure 10:Setup gauge span—Channel #2 (continued)
16.
Press PREVIOUS SCREEN to return to the
MAIN MENU
17. On
the
Main Menu
screen, press select to position the cursor in the top left corner
and type
316
and press ENTER
18. From
316 RAM TO UPPER RAM TRANSFER
screen, press 1 to activate the
transfer
19.
Screen 316 displays, type
003
in the menu number area and press ENTER
20. From
003 PRODUCT CODE SELECTION SCREEN
, type
0
and press ENTER to
return to product code 0
21.
Disconnect the write protect jumper, JP17. This protects the information in the
EEPROM.
Measurement units setup
009 SELECT UNITS
SELECT CHAN#1 UNITS
SELECT CHAN#2 UNITS
Figure 27: Measurement units setup screen
The measurement units for both the channels are set at screen 009. Under screen 9, the
weight and rate units list separately for Channel #1. The units for the second channel are
limited to speed and custom.
Custom units
If the engineering units required are not in the standard list, you can program a custom unit.
Please contact Ohmart for your specific needs.
Содержание W-4510
Страница 9: ...Preface viii W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 15: ...Preface xiv W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 17: ...Preface xvi W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 29: ...Introduction 12 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 36: ...Installation W 4510 Weigh Scale Technical Reference Manual 19 Figure 6 Typical Smart Pro dimensions...
Страница 48: ...Installation W 4510 Weigh Scale Technical Reference Manual 31 Figure 13 W 4510 terminal illustration...
Страница 125: ...Calibration 108 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 145: ...Diagnostics and repair 128 W 4510 Weigh Scale Technical Reference Manual Notes...
Страница 155: ...Appendix I Parameter blocks 138 W 4510 Weigh Scale Technical Reference Manual Notes...