Setting Up System Manager Terminals 2-9
101–1386–001
Edition 2
Note:
The Wyse 55ES terminal shipped with Octel servers emulates a Wyse 50. Therefore,
if you are using a Wyse 55ES, select option 1 for the terminal type.
8. After completing the fields, press the Send key to save the changes.
9. If you are setting up more than one SMT, repeat steps 4 through 8.
10. After making the changes to menu 6.3, reboot the server to save the changes as
follows:
a. Shut down the server. Refer to the appropriate section of the server service
manual for the system-shutdown procedure.
b. Start up the server.
c. When prompted to enter the boot command, type A to boot the server into normal
operation.
11. Verify that the server is operational and the CPU channels are active.
a. Log on to the server using the system manager password.
b. From the Main Menu, type 6 and press Return to access Menu 6 – Dialing and
Serial Channel Parameters.
c. To access menu 6.3, Define CPU Serial Channel, type 3 and press Return.
On the screen, the Active Type and Stored Type columns should display SMT for
the CPU channels you have entered. If these columns display SMT for the CPU
channels you have entered, the channels were configured correctly and are
operational.
If the Active Type column is blank but the Stored Type column displays SMT, the
reboot process was not correct. Reboot the server and verify that it is operational,
as described in steps 10 and 11.