2-8 Peripheral Equipment
101–1386–001
Edition 2
Configuring the CPU Serial Channels
After setting up the terminal and starting up the server, configure the CPU serial channels
on the server, using menu 6.3, Define CPU Serial Channel.
1. Log on to the server using the system manager password.
2. From the Main Menu, type 6 and press Return to access Menu 6 – Dialing and Serial
Channel Parameters.
3. To access menu 6.3, Define CPU Serial Channel, type 3, and press Return.
4. Type the number that corresponds to the CPU channel for the terminal being
configured in the Channel Number to Be Defined: field, and press Return.
Refer to Figure 2-1 or Figure 2-2 for the appropriate CPU channel associations for
your server.
5. In the Channel Type: field for the Octel Overture 250, type one of the following
values, then press Return:
1 – System Terminal
3 – Direct Integration
For the Octel Overture 350, type one of the following values, then press Return:
1 – System Terminal
2 – PC-based MTA
3 – Direct Integration
4 – From ACP for Terminals
6. In the CPU Baud Rate: field, type one of the following values, then press Return.
1 – 1200 Baud
2 – 9600 Baud
3 – 19200 Baud
The CPU baud rate must match the terminal baud rate. The recommended baud rate
is 9600.
7. In the Type of Terminal on This Channel: field, type one of the following values,
then press Return:
1 for a Wyse 50 or HP 700/43
2 for the AT&T 4425/5425 terminal
3 for a DEC VT102/VT220 terminal