OPERATION | Activating settings
8
www.ochsner.com | 982000-AIR-M2-M4-EN03.1
4. Activating settings
Settings are activated with the master controller on the
indoor unit (with graphic display or touchscreen), or via
a remote controller with touchscreen that is attached to
the wall.
The master controller is mounted in an easily accessible
plastic cover on the top of the indoor unit. Two buttons
are provided for controlling the menu, with an illuminated
graphic display.
11_01_200_701_01_01_001
5
4
3
1
11
6
7
9
8
10
2
Mo 09.01.17
10:02
-12.5C
22°C
52.5°C
32.5°C
Heating mode
OCHSNER OTE
MENU
1 Button A:
Press to go back one menu step (ESC)
2 Displays function of Button A or fault message
3 Operating status
4 Outdoor temperature
5 Date
6 Time
7 DHW temperature
8 Actual room temperature
9 System temperature
10 Displays function of Button B
11 Button B:
Turn to select from menu or to change setting
Press to confirm (
ENTER)
Pressing Button B on the right calls up the main menu
with a diagram of the heating system. Each heat consum-
er (heating circuit, DHW circuit) and each heat generator
(heat pump, electric booster heater, boiler etc.) has its own
menu and corresponding submenus.
Pressing Button A takes you back one step to the previous
menu.
You will find further information on operating the heat pump
control unit in the control unit‘s operating instructions which
are also supplied with the heat pump.
i
Information
The heat pump has no separate on/off switch. In
an emergency, the system must be shut down via
the specified safety devices.
»
Ensure easy access to the safety devices. It
must be possible to perform an emergency
shutdown at all times.
4.1 Operating costs
In the first two heating seasons, higher running costs are
to be expected (up to 50% more, depending on residual
moisture in the building). Enabling the screed drying pro-
gram will also increase operating costs further.
4.1.1 Flow temperatures
For optimum operation of your heat pump, you should aim
for the lowest possible heating flow temperatures (and also
DHW temperatures). The maximum system temperature
for your heat pump should be restricted to 60°C.
i
Information
Increasing the room temperature by 1°C results in
an increase in consumption of 5-7%.
4.1.2 Ventilation
Any ventilation should be intermittent, especially during
the heating period, and according to your own require-