INSTALLATION | Appliance maintenance
48
www.ochsner.com | 982000-AIR-M2-M4-EN03.1
12.2 Reset high limit safety cut-out
If the temperature sensor of the high limit safety cut-out
registers a heating water temperature of over 85°C, the
power supply to the internal electric booster heater is cut
off.
»
Check whether the high limit safety cut-out has
triggered.
»
Check the flow rate of the heating water.
»
Remedy the source of the fault.
»
Press the reset button on the rear of the appliance to
reset the high limit safety cut-out. The reset button
can be reached by hand from the left-hand side.
11_02_200_202_01_021
1
1 Reset button for high limit safety cut-out on rear of
appliance
13. Appliance maintenance
WARNING: Electrocution
For maintenance work, cut off the power supply to
the indoor and outdoor units of your heat pump.
i
Information
Ensure that the refrigerant circuit of your heat pump
is tested for leaks once a year (in acc. with Regu-
lation (EU) no. 517/2014).
»
Ensure year-round access to soldered joints in
the refrigerant circuit.
»
Document the results of the leakage test in the
system test report.
We recommend arranging for an inspection and if neces-
sary a service on the heat pump to be conducted once
a year. We draw your attention to the fact that statutory
regulations require regular testing of heating systems by
the system user.
The refrigerants used in OCHSNER heat pumps are
non-flammable, non-toxic and ozone neutral.
Heat pumps
are refrigeration equipment and are subject to the pro-
visions of the F-gas Regulations (Regulation (EU) no.
517/2014). OCHSNER Customer Service will be pleased to
help in carrying out maintenance and testing, in particular
as required by the F-gas Regulations.
You can find more
information at www.ochsner.com.
We recommend testing the heating water system pressure
and correcting it if necessary (pressure too high/low).
We recommend adjusting the charge pressure in the dia-
phragm expansion vessel (DEV) on the system accordingly
(system height).
We recommend monitoring the flow rate of the heat sink
system (WNA) and if necessary the heat source system
(WQA) using the flow meters specified by OCHSNER.
We recommend that when non-routine work takes place
requiring refilling (e.g. system alteration or pipe breakage),
a current water assessment be prepared and the heat sink
system be refilled on the basis of this.
13.1 Testing safety valve
i
Information
The indoor unit has an internal safety valve (DHW,
heating).
»
Observe the national and regional regulations
regarding the prescribed regular operational
tests.
»
Remove the left-hand appliance casing panel to gain
access to the internal safety valve (see „Disassem-
bling the appliance casing“ on page 26).
»
To test, turn the red knob on the safety valve until wa-
ter emerges from the safety valve drain.