The table below should be used to select the required cable conductor size per
junction box. If in doubt always select the next larger conductor size up (i.e. the
next lower AWG number).
For long runs using the thicker gauges it may be necessary to drop down to
a slightly smaller gauge cable near to the OceanDMX junction box to allow
connection into the unit (keeping the long run in the thicker gauge cable to
avoid voltage drops). Ensure all connections / joints are watertight, and
suitable for the current load.
The supply cable must be protected by a suitable fuse or breaker
SUPPLY CABLE CONDUCTOR SIZE CHART
CABLE
LENGTH
(FEET)
CIRCUIT CURRENT
2 AMP
4 AMP
6 AMP
8 AMP
10 AMP
12 AMP
14 AMP
16 AMP
0-5
18 AWG
18 AWG
16 AWG
16 AWG
16 AWG
14 AWG
14 AWG
14 AWG
10-15
18 AWG
18 AWG
16 AWG
16 AWG
14 AWG
14 AWG
14 AWG
14 AWG
15-20
18 AWG
18 AWG
16 AWG
14 AWG
14 AWG
14 AWG
12 AWG
12 AWG
20-25
18 AWG
16 AWG
14 AWG
14 AWG
12 AWG
12 AWG
12 AWG
10 AWG
25-30
18 AWG
16 AWG
14 AWG
12 AWG
12 AWG
10 AWG
10 AWG
10 AWG
30-35
18 AWG
14 AWG
14 AWG
12 AWG
10 AWG
10 AWG
10 AWG
8 AWG
35-40
18 AWG
14 AWG
12 AWG
12 AWG
10 AWG
10 AWG
8 AWG
8 AWG
40-45
16 AWG
14 AWG
12 AWG
10 AWG
10 AWG
8 AWG
8 AWG
8 AWG
45-50
16 AWG
14 AWG
12 AWG
10 AWG
10 AWG
8 AWG
8 AWG
8 AWG
50-55
16 AWG
12 AWG
10 AWG
10 AWG
8 AWG
8 AWG
8 AWG
4 AWG
55-60
16 AWG
12 AWG
10 AWG
10 AWG
8 AWG
8 AWG
4 AWG
4 AWG
60-65
14 AWG
12 AWG
10 AWG
8 AWG
8 AWG
8 AWG
4 AWG
4 AWG
65-70
14 AWG
12 AWG
10 AWG
8 AWG
8 AWG
4 AWG
4 AWG
4 AWG
70-75
14 AWG
12 AWG
10 AWG
8 AWG
8 AWG
4 AWG
4 AWG
4 AWG
75-80
14 AWG
10 AWG
10 AWG
8 AWG
4 AWG
4 AWG
4 AWG
2 AWG
80-85
14 AWG
10 AWG
8 AWG
8 AWG
4 AWG
4 AWG
4 AWG
2 AWG
85-90
14 AWG
10 AWG
8 AWG
8 AWG
4 AWG
4 AWG
2 AWG
2 AWG
90-95
14 AWG
10 AWG
8 AWG
8 AWG
4 AWG
4 AWG
2 AWG
2 AWG
95-100
12 AWG
10 AWG
8 AWG
4 AWG
4 AWG
4 AWG
2 AWG
2 AWG