105
-
TROUBLESHOOTING
TEST PROCEDURE
SLOW CYLINDER SPEED
PROBLEM
CAUSE
CHECK
REMEDY
Operating Pressure
is less than 3,700
psi (
255 bar
).)
Carrier hydraulic
circuit relief valve.
Measure the carrier
circuit relief valve with
the pressure to close
shut-off valve in the
"OFF"
position
Adjust or replace the
carrier circuit relief
valve. The setting for
the relief valve must
be 200 psi (
14 bar
),
minimum, above the
M35 Processor
operating pressure.
M35 Processor
relief valves
Measure the relief
valves with the shut-
off valves on the
carrier in the
"ON"
position. Check
pressure with the
jaws fully open and
fully closed.
Setting should be
3,700 psi (
255 bar
).
Check relief
cartridges for
tightness.
Tighten the relief
valve cartridges.
Check relief
cartridges for mis-
adjustment.
Reset to 3,700 psi
(255 bar
). If unable
to adjust, replace the
cartridge.
Check the o-rings and
backup rings of the
relief valve cartridges.
Replace the o-rings
and backup rings of
both relief valve
cartridges.
Содержание M35G