-
100
-
TROUBLESHOOTING
INTENSIFIER CHECKS
(unit does not click)
INTENSIFIER CHECKS
PROBLEM
CAUSE
CHECK
REMEDY
Intensifier does not
click
M35 Processor
relief valves
Check relief
cartridges for
tightness.
Tighten the relief
valve cartridges.
Check relief
cartridges for mis-
adjustment.
Reset to 3,700 psi
(
255 bar
). If unable
to adjust, replace the
cartridge.
Check the o-rings and
backup rings of the
relief valve cartridges.
Replace the o-rings
and backup rings of
both relief valve
cartridges.
Booster control
valve assembly.
Dis-assemble the
main valve and
inspect the spring,
plungers and for free
movement of the
spool.
Polish or replace as
necessary.
Booster assembly
Check poppets and
seats.
Replace poppets
and seats as
necessary.
Check all o-rings and
backup rings.
Replace all o-rings
and backup rings.
Содержание M35G
Страница 13: ... 13 SERIAL NUMBER LOCATION M35 ...
Страница 115: ... 115 WARRANTY STATEMENTS ...
Страница 116: ... 116 WARRANTY STATEMENTS ...
Страница 118: ... Copyright 2018 NPK Construction Equipment Inc www npkce com M000 9601B M35 Material Processor Instruction Manual 10 18 ...