95
-
TROUBLESHOOTING
TROUBLESHOOTING GUIDE FOR LOW POWER
RELIEF VALVE CHECKS
LOW POWER CHECKS
PROBLEM
CAUSE
CHECK
REMEDY
Operating pressure
is at 3,700 psi (
255
bar
),
but the
intensifier does not
click.
Booster control
valve assembly.
Dis-assemble the
main valve and
inspect the spring,
plungers and for
free movement of
the spool.
Polish or replace as
necessary.
Booster assembly
Dis-assemble the
main valve and
inspect the piston
assembly, seals,
poppets and seats.
Polish or replace as
necessary.