OEM7 SPAN Installation and Operation User Manual v14
304
APPENDIX E LN-200 IMU in SPAN IMU Enclosure
The following procedure provides the necessary information to install the LN-200 sensor (NovAtel part number
80023515) into the SPAN IMU enclosure (NovAtel part number 01017656) using the LN-200 wiring harness
(NovAtel part number 01017655). The steps required for this procedure are:
l
Disassemble the SPAN IMU Enclosure
l
Install the LN-200 Sensor Unit
l
Make Electrical Connections
l
Reassemble the SPAN IMU Enclosure
Important!
: Ensure you use a ground strap before installing the internal circuit boards. Do NOT scratch
any surfaces of the unit.
Figure 137: Required Parts
Reference Description
1
SPAN IMU Enclosure
2
LN-200 Wiring Harness
3
LN-200 Sensor Unit
E.1 Disassemble the SPAN IMU Enclosure
The SPAN IMU disassembly steps are as follows:
1. Remove the six bolts from the top cover using a hex key, as shown in