APPENDIX A IMU Technical Specifications
OEM7 SPAN Installation and Operation User Manual v14
159
A.4.3 IMU-HG1900 Electrical and Environmental
Electrical
IMU Power Consumption
7.5 W (typical)
IMU Input Voltage
+10 to +34 VDC
IMU Interface
RS-422
Connectors
Power
SAL M12, 5 pin, male
Data
SAL M12, 5 pin, female
Wheel Sensor
SAL M12, 8 pin, male
Table 53: IMU-HG1900 Electrical Specifications
Environmental
Operating Temperature
-40°C to +55°C
Storage Temperature
-40°C to +80°C
Humidity
MIL-STD-810G(Ch1), Method 507.6
Random Vibe
MIL-STD-810G(Ch1), Method 514.7 (2.0 g)
Environment
MIL-STD-810G(Ch1), Method 512.6
IEC 60529 IP67
Table 54: IMU-HG1900 Environmental Specifications
A.4.4 IMU-HG1900 Cables
IMU-HG1900 Interface Cable
The IMU-HG1900 uses the IMU Enclosure Interface Cable. Refer to
for details about this cable.
IMU-HG1900 Power Cable
The IMU-HG1900 uses the IMU Enclosure Power Cable. Refer to
on page 178 for
details about this cable.
IMU-HG1900 Wheel Sensor Cable
The IMU-HG1900 uses the IMU Enclosure Wheel Sensor Cable. Refer to
IMU Enclosure Wheel Sensor Cable
on page 179 for details about this cable.