Chapter 2 SPAN Installation
OEM7 SPAN Installation and Operation User Manual v14
61
Figure 11: Connect the STIM300 IMU to the MIC (OEM Cable Kit: 01019174)
Connect Power to the MIC
Connect a +10 to +30 VDC power supply to the power connector (P101) on the MIC. See
page 262 for pinout information for the power connector.
This connection provides power to the MIC, the OEM719 and the IMU.
Connect the Input and Output Signals
All of the communication connections to the MIC and the OEM719 receiver are available on the communications
connector (P601) on the MIC. These connections include:
l
MIC serial port
l
OEM719 serial port (COM2)
l
USB port
l
Event1 trigger input
l
Event2 trigger input
l
1 PPS (Pulse Per Second) output
l
VARF (Variable Frequency) output
l
Reset input
l
Position Valid output
See
on page 262 for the pinouts of the communications connector.
All signal I/O with the exception of the USB port are at LVCMOS levels. To connect the MIC to devices
that use other signals levels, such as a computer with an RS-232 serial port, an interface circuit that con-
verts LVCMOS to the other signal level must be used.
Use a twisted pair for the USB port connection and keep the wires as short as possible.
2.2.2 Install a MIC in a Standalone Configuration
In a standalone configuration, the MIC is mounted separately from the OEM7 receiver.