APPENDIX A IMU Technical Specifications
OEM7 SPAN Installation and Operation User Manual v14
175
A.6.4 IMU-ISA-100C Electrical and Environmental
Electrical
IMU Power Consumption
18 W (typical)
IMU Input Voltage
+10 to +34 VDC
IMU Interface
RS-422
Connectors
Power
SAL M12, 5 pin, male
Data
SAL M12, 5 pin, female
Wheel Sensor
SAL M12, 8 pin, male
Table 70: IMU-ISA-100C Electrical Specifications
Environmental
Operating Temperature
-40°C to +55°C
Storage Temperature
-40°C to +85°C
Humidity
MIL-STD-810G, Method 507.5
Random Vibe
MIL-STD-810G, Method 514.6 (2.0 g)
Environmental
IEC 60529 IP67
Table 71: IMU-ISA-100C Environmental Specifications