Chapter 2 SPAN Installation
OEM7 SPAN Installation and Operation User Manual v14
57
Figure 6: Basic Set Up – MIC in Stack Up Configuration
Ref
Connector
Part Number
Mating Connector
Description
1
P101
43650-0313
(Molex)
43645-0300
(Molex)
Connects to the MIC power supply.
This connection provides power to the MIC and the
OEM719 receiver. (user supplied cable)
2
P601
53780-2070
(Molex)
51146-2000
(Molex)
Connects to HG1700, HG1900, HG1930 and STIM300
IMUs. (NovAtel supplied cable kit)
3
P701
53780-1070
(Molex)
51146-1000
(Molex)
Connects to ADIS-16488 IMUs.
(NovAtel supplied cable kit)
4
P301
501571-3007
(Molex)
501189-3010
(Molex)
Connects the MIC and OEM719 communication signals
to the user system. (user supplied cable)
5
J301
ASP-163577-
01
(Samtec)
N/A
Connects to the main connector (P1701) on an OEM719
receiver. J301 is on the bottom of the MIC card
For information about the MIC connectors and pin-outs, see