Chapter 2 SPAN Installation
OEM7 SPAN Installation and Operation User Manual v14
64
An IMU mounting PCB is not used with the STIM300 IMU.
2. Connect the IMU-to-MIC interface cable to the IMU.
3. Connect the IMU-to-MIC interface cable to the IMU connector on the MIC.
l
Use the 10 pin locking connector (P701) for the ADIS-16488 IMUs.
See
Figure 15: Connect the ADIS-16488 IMU to the MIC (OEM Cable Kit: 01019007)
l
Use the 20 pin locking connector (P601) for the HG1700, HG1900, HG1930 or STIM300 IMU.
See
Figure 13: Connect the HG1900 IMU to the MIC (OEM Cable Kit: 01018871)
Connect the HG1930 IMU to the MIC (OEM Cable Kit: 01018869)
below or
STIM300 IMU to the MIC (OEM Cable Kit: 01019174)
Figure 13: Connect the HG1900 IMU to the MIC (OEM Cable Kit: 01018871)
Figure 14: Connect the HG1930 IMU to the MIC (OEM Cable Kit: 01018869)
The ADIS-16488 and STIM-300 are capable of a direct connection with OEM7 receivers, when a proper
connection is available (ADIS-16488 = SPI, STIM300 = serial RS-422). If using the MIC connection is
necessary, the following diagrams detail the cable connection parts between the MIC and IMU.