Chapter 2 SPAN Installation
OEM7 SPAN Installation and Operation User Manual v14
65
Figure 15: Connect the ADIS-16488 IMU to the MIC (OEM Cable Kit: 01019007)
Figure 16: Connect the STIM300 IMU to the MIC (OEM Cable Kit: 01019174)
Connect the MIC to a Receiver
1. Using a customer supplied wiring harness, connect the MIC serial port to a serial port on the OEM7 receiver.
The MIC serial port is available on the communications connector (P301) of the MIC.
See
on page 262 for the pinouts of the communications connector. See the
ation and Operation User Manual
for information about connecting a serial port to the receiver.
All signal I/O on the MIC, with the exception of the USB port, are at LVCMOS levels.
To connect the MIC to devices that use other signals levels, such as a computer with
an RS-232 serial port, an interface circuit that converts LVCMOS to the other signal
level must be used.
OEM719
OEM7600
OEM7700
OEM7720
All of the COM ports on these receivers use LVCMOS levels and are signal level compatible
with the MIC serial port.
OEM729
Use COM2 or COM3 of the OEM729 receiver to connect the MIC serial port. These COM
ports use LVCMOS levels and are signal level compatible with the MIC serial port.
COM1 on the OEM729 receiver can use RS-232 levels (default) or RS-422 levels and is not
signal level compatible with the MIC serial port.
Table 13: COM Port Recommendations