APPENDIX C LN-200 IMU in Universal Enclosure
OEM7 SPAN Installation and Operation User Manual v14
295
Figure 124: Making Connections
Make sure the tape of the harness is positioned for maximum protection.
4. While carefully holding the body over the bracket, connect the internal cable harness to the board assembly,
as shown in
Figure 125: Connect Internal Cable Harness
Figure 125: Connect Internal Cable Harness
5. Clean the surface of the enclosure body, where it will mate with the O-rings, using isopropyl alcohol. While
ensuring all wires will fit inside the bracket without being pinched, align the reference markers and pilot
holes/screws of the enclosure body and base, and carefully lower the body onto the base, observing the O-