APPENDIX B HG1700 IMU in Universal Enclosure
OEM7 SPAN Installation and Operation User Manual v14
287
Figure 111: Assemble Into Enclosure Body
5. Connect the internal cable harness to the enclosure body, as shown in
Figure 112: Fasten Internal Cable Har-
on the next page. During this step, ensure the connector O-ring (supplied with the connector of the
internal cable harness) remains flat within the connector’s groove, and make sure the groove is clean and
free of debris. Fasten the connector to the enclosure body wall using the jam nut supplied with the con-
nector. Apply thread-locking fluid then, with a 30 mm socket, tighten the jam nut to 6.9 N-m (61 lb-in/5.1 lb-
ft).