Installing replaceable parts 7-85
Replacing the teladapt connector for datajack
If the teladapt connector on the APC datajack module
becomes corroded or jammed with foreign matter, it is not
necessary to replace the entire unit.
The teladapt, in its plastic shell, can be removed from the
datajack housing and replaced using the following
procedure:
1. Make sure the connect button is up. The release button
should be pushed in. This means there is no power to
the datajack unit.
2.
Remove the set screw located on the bottom of the slid
ing plate shown in Figure 7-69, and to the side. This re
leases the bottom plate.
3. Slide the plate forward, out of the unit.
Figure 7-69: Replacing the teladapt on the datajack module
Datajack module
(attached to terminal housing)
Teladapt connector
Sliding plate
Set screw is located on bottom, to the side
4. Grasp the teladapt connector by the front and back and
pull it straight down, out of the housing.
5. Line the replacement module up with the guides on the
sides of the datajack unit.
• The connectors should be facing the front and at
the top.
• There are two small holes at the top of the tel
adapt. Push it up, into the datajack housing.
Millennium multi-pay terminal installation, operation, and maintenance guide
Содержание Millennium multi-pay M1211
Страница 3: ...iv NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 17: ...xviii Table of contents NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 21: ...t ATG 4 About this guide I NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 57: ...1 36 Describing the terminal NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 87: ...2 30 Mounting the terminal NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 167: ...Troubleshooting strategies 6 13 Millennium multi pay terminal installation operation and maintenance guide...
Страница 168: ...i 6 14 Troubleshooting strategies NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 268: ...7 92 Installing replaceable parts NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 281: ...Customer orderable parts 9 9 Millennium multi pay terminal installation operation and maintenance guide...
Страница 282: ...9 10 Customer orderable parts NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 283: ...Customer orderable parts 9 11 Figure 9 4 Auxiliary view multi pay terminal chassis...
Страница 304: ...A 16 Appendix A List of alarms NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 324: ...C 10 Appendix C Regulatory notices NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 349: ......