Installing replaceable parts 7-47
Replacing the coin validator
The coin validator has sensors which check inserted coins
to make sure they are valid for the terminal. The terminal
can be configured to accept American or Canadian coinage.
To replace this module:
1. This procedure assumes you have:
• followed the directions in
Preparing the terminal
for maintenance
and
Opening the terminal.
The
power is disconnected.
A
Be sure you upload CDRs before you do this
procedure.
You will need to run the INSTALL terminal-
configuration routine if you replace this unit.
• It is not necessary to remove the PCP assembly to
work with the validator, however, you might find it
more convenient to do so. Follow the instructions
in
Removing the PCP assembly.
Refer to Figure 7-38 for validator cable locations.
Figure 7-38: Validator cable connections
Coin validator —
Validator/
escrow
| f
| -------- Rear housin9
connection
Escrow PCP —
Telephony PCP
(Control PCP is on
the other side of the
PCP assembly)
] y
/
h
cj A
W f l f
t0 control board
A 1
II
(thread under the
assembly)
I
i
\
f
©
Millennium multi-pay terminal installation, operation, and maintenance guide
Содержание Millennium multi-pay M1211
Страница 3: ...iv NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 17: ...xviii Table of contents NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 21: ...t ATG 4 About this guide I NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 57: ...1 36 Describing the terminal NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 87: ...2 30 Mounting the terminal NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 167: ...Troubleshooting strategies 6 13 Millennium multi pay terminal installation operation and maintenance guide...
Страница 168: ...i 6 14 Troubleshooting strategies NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 268: ...7 92 Installing replaceable parts NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 281: ...Customer orderable parts 9 9 Millennium multi pay terminal installation operation and maintenance guide...
Страница 282: ...9 10 Customer orderable parts NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 283: ...Customer orderable parts 9 11 Figure 9 4 Auxiliary view multi pay terminal chassis...
Страница 304: ...A 16 Appendix A List of alarms NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 324: ...C 10 Appendix C Regulatory notices NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 349: ......