A-4 Appendix A: List of alarms
Table A -1: List of alarms (continued)
Description:
Occurs when the terminal powers up after a power interruption
longer than two seconds, with no other errors outstanding.
• It occurs only when the terminal is fully installed, to prevent
false alarms while toggling power during maintenance.
• The VFD displays
out of service,
but there is no other
visual indication this alarm has been sent.
Example:
The terminal attempts to contact the Millennium
Manager, but gets no response. The terminal continues trying
until the retry-attempts threshold is met. The terminal goes out
of service. If there is a power interruption during this time, the
terminal displays
out of service
and the power fail alarm
is sent to the Millennium Manager when communications
resumes.
Action:
Check the terminal for abuse or fraud.
If the problem continues:
1. Send the CDRs to the Millennium Manager.
2. Replace the control PCP.
3. Perform the INSTALL terminal-configuration routine.
Description:
Occurs when there is a communication problem with the VFD.
• When the control PCP tries to send characters to the display,
the display indicates it is communicating with the control
microprocessor.
• There is no visual indication on the display that the alarm has
been sent. However, this problem may cause the display to
freeze and the terminal to go out of service.
• Likely causes are a damaged ribbon cable or a defective
control PCP.
Description continues on the next page
NTP: 506-6501-203 Issue: 00.01 Status: Standard Date: January 1997
Содержание Millennium multi-pay M1211
Страница 3: ...iv NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 17: ...xviii Table of contents NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 21: ...t ATG 4 About this guide I NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 57: ...1 36 Describing the terminal NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 87: ...2 30 Mounting the terminal NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 167: ...Troubleshooting strategies 6 13 Millennium multi pay terminal installation operation and maintenance guide...
Страница 168: ...i 6 14 Troubleshooting strategies NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 268: ...7 92 Installing replaceable parts NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 281: ...Customer orderable parts 9 9 Millennium multi pay terminal installation operation and maintenance guide...
Страница 282: ...9 10 Customer orderable parts NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 283: ...Customer orderable parts 9 11 Figure 9 4 Auxiliary view multi pay terminal chassis...
Страница 304: ...A 16 Appendix A List of alarms NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 324: ...C 10 Appendix C Regulatory notices NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 349: ......