Installing replaceable parts 7-79
Attaching the ISWs, continued
b) Grasp the top portion of the terminal block
and pull it carefully away from the board.
c) Snap the block to the upper arm of the link
assembly. This secures the upper terminal
block in place so you can use both hands to
attach the wires.
d) Remove the protective tape from the ISWs
and strip the end of each wire.
e) Connect the ISWs to the terminal block. Use
a small screwdriver to connect the leads.
CAUTION
?
Connecting power to
the terminal
Ensure the proper polarity when connecting the
supplementary power supply. Reverse polarity
does not cause damage, but the terminal does not
work if the polarity is incorrect.
Take the usual precautions with the wiring.
Conceal the wiring near the telephone or use ap
proved moulding or tubing.
Locate protectors and connecting blocks where
they will be inaccessible to the terminal user.
9. Once the ISWs are attached, plug the terminal block
into the header J2 on the bottom of the IAS PCP. The
IAS module can be slid upward in the extrusion to allow
more room to plug in the connector.
10. Route the ISW to the bottom of the rear housing to pre
vent interference with the PCP assembly.
11. To prevent the IAS PCP from sliding up in its mount, in
sert a cable tie through the hole at the top of the IAS
board mount and tie its ends together. Trim off the ex
cess.
12. Reconnect the rear terminal PCP connector to the con
trol PCP to reconnect the power and close and lock the
housing assembly. Refer to
Opening the terminal,
if
necessary.
Millennium multi-pay terminal installation, operation, and maintenance guide
Содержание Millennium multi-pay M1211
Страница 3: ...iv NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 17: ...xviii Table of contents NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 21: ...t ATG 4 About this guide I NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 57: ...1 36 Describing the terminal NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 87: ...2 30 Mounting the terminal NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 167: ...Troubleshooting strategies 6 13 Millennium multi pay terminal installation operation and maintenance guide...
Страница 168: ...i 6 14 Troubleshooting strategies NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 268: ...7 92 Installing replaceable parts NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 281: ...Customer orderable parts 9 9 Millennium multi pay terminal installation operation and maintenance guide...
Страница 282: ...9 10 Customer orderable parts NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 283: ...Customer orderable parts 9 11 Figure 9 4 Auxiliary view multi pay terminal chassis...
Страница 304: ...A 16 Appendix A List of alarms NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 324: ...C 10 Appendix C Regulatory notices NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 349: ......