7-62 Installing replaceable parts
To distinguish this coin box rail from the old model, the new
model has been painted a silver color.
This new rail will eventually replace the existing rail.
However, the coin funnel gasket
is only necessary when non-Nortel-issue coin box lids are
used.
Replacing the security PCP
The security PCP is located inside the coin vault. It has two
microswitches. One monitors the coin box and the other, the
coin vault lock. This module seldom fails, so there are no
specific alarms to indicate a security PCP failure.
A failure can be deduced if all other coin box factors have
been eliminated as the cause of alarms or collection prob
lems. Refer to Chapter 6 for troubleshooting suggestions.
1. This procedure assumes you have:
• arranged for a coin box pickup
• followed the directions in
Preparing the terminal
for maintenance
and
Opening the terminal.
The
power is disconnected by removing the upper ter
minal block at the rear terminal PCP.
2. Locate the cable that comes up through the bottom of
the housing from the security PCP and hooks into the
rear terminal PCP. Refer to Figure 7-52.
a) Remove the coin box security PCP cable (J31) from
the rear terminal PCP connector (J30).
b) Remove the wires from any cable clamps.
3. Carefully guide the security PCP wires and connector
through the opening in the vault top.
4. Close, but do not lock, the front housing assembly.
NTP: 506-6501-203 Document issue: 00.01 Status: Standard Date: January 1997
Содержание Millennium multi-pay M1211
Страница 3: ...iv NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 17: ...xviii Table of contents NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 21: ...t ATG 4 About this guide I NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 57: ...1 36 Describing the terminal NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 87: ...2 30 Mounting the terminal NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 167: ...Troubleshooting strategies 6 13 Millennium multi pay terminal installation operation and maintenance guide...
Страница 168: ...i 6 14 Troubleshooting strategies NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 268: ...7 92 Installing replaceable parts NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 281: ...Customer orderable parts 9 9 Millennium multi pay terminal installation operation and maintenance guide...
Страница 282: ...9 10 Customer orderable parts NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Страница 283: ...Customer orderable parts 9 11 Figure 9 4 Auxiliary view multi pay terminal chassis...
Страница 304: ...A 16 Appendix A List of alarms NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 324: ...C 10 Appendix C Regulatory notices NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Страница 349: ......