Installation / 37
P0881594 Issue 01
MICS-XC Norstar-Companion Installer Guide
Note: Up to 60 portables can be installed on a Norstar wireless
system. Each portable telephone must be registered
before it can be used. By default, no Companion
portables are assigned to the DNs. The range of portable
extensions available for wireless registration is 637 to
666. (This means that the digit 6 is not available as a
destination code.)
Installing external antennas and lightning surge
arrestors
When installing external antennas and lightning surge
arrestors:
•
The antenna should always be mounted vertically (see
figure on page 39).
•
Use #8, 12 mm to 50 mm (
1
/
2
-in. to 2 in.) screws to mount
the antenna bracket and lightning surge arrestor bracket to
the wall.
•
Always ensure that the antenna is clear of any adjacent
obstruction, particularly metal. If more than one external
antenna is used at a cell center, space them at least 1 m (40
in.) apart to avoid radio interference problems.
•
When running the coaxial cable inside or outside, do not
kink, stretch, or crush the cable. This will seriously affect
its performance. The minimum recommended bending
radius is 200 mm (8 in.).
•
The coaxial cable length must not exceed 10 m.
•
Use RG-58AU coaxial cables to connect the antennas to
the Base Stations.
p0881594.book Page 37 Tuesday, August 25, 1998 3:59 PM
Содержание Companion MICS-XC
Страница 2: ......
Страница 12: ...6 Norstar Companion basics MICS XC Norstar Companion Installer Guide P0881594 Issue 01...
Страница 50: ...44 Installation MICS XC Norstar Companion Installer Guide P0881594 Issue 01...
Страница 52: ...46 Powering up the system MICS XC Norstar Companion Installer Guide P0881594 Issue 01...
Страница 92: ...86 Registering individual portables MICS XC Norstar Companion Installer Guide P0881594 Issue 01...
Страница 137: ......