42 / Installation
MICS-XC Norstar-Companion Installer Guide
P0881594 Issue 01
Lightning surge arrestor and bracket
Before you connect the ground lead to the lightning surge
arrestor, attach it to an approved ground.
Tip -
The recommended wire gauge is 4 mm (6
AWG). Connect the ground lead to the building
ground. Do not connect to a ground rod or series of
ground rods. If you cannot connect the ground lead
to the building ground, connect it to the steel frame
of the building. The connection should be no more
than 1.8 to 3 m (6 to 10 ft.).
You can also connect the ground lead to the 120 V
AC conduit (which is connected to the building
ground), but this is not a preferred installation.
The connector between the antenna and the
lightning surge arrestor and between the lightning
surge arrestor and the Base Station is a proprietary
BNC connector and requires alignment before a
connection can be made.
p0881594.book Page 42 Tuesday, August 25, 1998 3:59 PM
Содержание Companion MICS-XC
Страница 2: ......
Страница 12: ...6 Norstar Companion basics MICS XC Norstar Companion Installer Guide P0881594 Issue 01...
Страница 50: ...44 Installation MICS XC Norstar Companion Installer Guide P0881594 Issue 01...
Страница 52: ...46 Powering up the system MICS XC Norstar Companion Installer Guide P0881594 Issue 01...
Страница 92: ...86 Registering individual portables MICS XC Norstar Companion Installer Guide P0881594 Issue 01...
Страница 137: ......