Installing the Agent Greeting Card Page 39 of 84
Agent Greeting Card Installation Guide
Note: It is recommended that the operator disable all Meridian Modular or
Meridian Digital units in LD 32 before moving (MOV) or outing (OUT) them in
LD 11. This is because the Agent Greeting card does not receive any messages from
the Meridian 1 on a move or an out. This can lead to Agent Greeting ports being left
in an indeterminate state, as no indication that the port has been moved or outed is
received by the Agent Greeting card.
Adding Agent Greeting service to agent sets
LD 11 - The agent set must be configured to use Agent Greeting functionality. This
is done by adding the AGRA Class of Service to the set.LD 11 Configuring agent
sets with the Agent Greeting feature
Prompt
Response
Description
REQ:
NEW CHG
Add or change.
TYPE:
xxxx
Agent set type
CUST:
0–99
Customer Number
TN
l s c u
Terminal Number
...
CLS
AGRA
MOAA
Agent Greeting Allowed
Mute On Agent Answer
Содержание Agent Greeting NTVQ09BA