Page 36 of 84 Installing the Agent Greeting Card
NTPH13AA_Install 3.02 September 2006
Switch configuration for Agent Greeting ports
Enable Package #152 – For Agent Greeting to be configured, the Flexible Services
Port (FXSP) package, number 152, must be enabled.
Note: The Agent Greeting Ports appear to the Meridian switch as M2616 digital
sets and must be configured as such. These sets are grouped together using MADN,
and are further grouped together using the FXSP (Flexible Services Port) field as
described below.
The sequence of configuration is:
1
Select MADNs for the TUI ports in the Agent Greeting configuration. A new
MADN number is required for each 30 ports, although it is probably easier to
assign a new MADN for each Agent Greeting card in a multicard group. All
unassigned DNs may be listed via LD 20, REQ PRT, TYPE LUDN.
2
Configure the Agent Greeting Ports as type M2616 in LD 11 as described
below.
3
Assign the MADN to the FXSDN group in LD 15.
4
Enable the Agent Greeting cards in LD 32.
5
Enable the Agent Greeting Class of Service on the Agent sets in LD 11 (for
digital sets).
LD 11 – The Agent Greeting units 0 to 23 (on each card if in a Multi-Card
installation) are configured as Meridian Modular M2616 sets with configuration
shown in Table 6.
Table 6: LD 11 Agent Greeting port configuration
Prompt
Response
Description
REQ:
NEW CHG
Add or change.
TYPE:
2616
Ports must be configured as M2616.
TN
l s c u
Terminal Number
DES
d..d
Designator
CUST
0-99
Customer Number
...
Содержание Agent Greeting NTVQ09BA
Страница 2: ...Page 2 of 84 ...
Страница 4: ...Page 4 of 84 Publication history NTPH13AA_Install 3 02 September 2006 ...
Страница 8: ...Page 8 of 84 List of figures NTPH13AA_Install 3 02 September 2006 ...
Страница 10: ...Page 10 of 84 NTPH13AA_Install 3 02 September 2006 ...
Страница 84: ...Page 84 of 84 Precautions for handling circuit cards NTPH13AA_Install 3 02 September 2006 ...
Страница 85: ......