Configure E1/T1 ports on a Call Server
91
3
Enter the responses shown in
D-channel interface configuration (LD 17)" (page 91)
Table 21
DPNSS/DASS D-channel interface configuration (LD 17)
Prompt
Response
Description
REQ
CHG
Change existing data.
TYPE
ADAN
Action device and number.
ADAN
NEW DCH xx
Add a D-channel on logical port 0 - 15.
CTYP
DCHI
D-channel configuration on DCHI card Type (NTAK93AB).
MG_CARD
supl sh card
The physical card for the digital loop association to the PRI
Gateway.
The format is: superloop, shelf number, card number.
ATTENTION
If using a NTAK93AB daughterboard, even card
numbers are applicable (2, 4, 6, 8). If using the onboard
DPNSS/DASS, odd and even numbers are applicable (1,
2, 3, 4, 5, 6, 7, 8).
PORT
1
Port number of the NTAK93AB for DPNSS/DASS
D-channel.
For a DPNSS/DASS D-channel, the port is always 1.
...
...
DES
DPNSS
Designator (up to 16 alphanumeric characters).
DPNS
YES
Digital Private Network Signaling.
...
...
--End--
D-channel configuration example
Table 22 "D-channel configuration example " (page 92)
shows a
configuration example in the PRI Gateway of two D-channel interfaces on
the same downloadable D-channel daughterboard that serves two PRI2
loops as follows:
•
Two PRI2/E1 loops (numbered 200 and 201) are configured (for
example, superloop 4 0). Each loop simulates different physical cards
(3 and 4).
•
Two D-channel interfaces are defined to serve two different
loops/spans (200 and 201). They use the same downloadable
D-channel daughterboard (port 0 and port 1) simulated through the
physical location of card 4.
Nortel Communication Server 1000
Media Gateway 1000E PRI Gateway Installation and Commissioning
NN43041-311 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.
Содержание 1000E PRI