Configure E1/T1 ports on a Call Server
95
Prompt
Response
Description
- SREF
Card
Card number of PRI containing the Secondary Clock
Reference for the second IPMG.
To modify, use the CHG command (you can change the
PREF only if you change the MGCLK).
...
...
TRSH
0 - 15
Create or change a PRI threshold set.
Enter this number in LD 17 when defining the PRI loop.
RALM
1–(3)–128
Yellow alarm (remote alarm) 24-hour threshold.
Number of remote alarm clear signals received in 24 hours.
...
...
--End--
Use
Procedure 24 “Configuring PRI2 data block for system timers using
to configure the 2 Mb/s PRI2 data block including system
timers.
Procedure 24
Configuring PRI2 data block for system timers using LD 73
Step
Action
1
Log on to the CS 1000E.
2
To access LD 73, enter:
LD 73
3
Enter the responses shown in
Table 25 "Configuration for PRI2
data block system timers (LD 73)" (page 95)
Table 25
Configuration for PRI2 data block system timers (LD 73)
Prompt
Response
Description
REQ
aaa
Request (aaa = CHG, END, NEW, OUT, or PRT).
TYPE
PRI2
DTI2 and JDMI are not supported for MGP.
FEAT
SYTI
Feature = SYTI (System Timers)
...
...
MGCLK
sl s c
Superloop, shelf, card number of PRI2 containing the
Primary Clock Reference for the first IPMG.
The card number (1 - 8) should match the span number
configured through the Web interface.
- PREF
Card
Card number of PRI2 containing the Primary Clock
Reference for the first IPMG.
Nortel Communication Server 1000
Media Gateway 1000E PRI Gateway Installation and Commissioning
NN43041-311 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.