Procedure 13
Configuring Media Gateway Controller Tone and Conference using LD 17
Step
Action
1
Log on to the CS 1000E Call Server.
2
To access LD 17, enter:
LD 17
3
Enter the responses shown in
and Conference configuration (LD 17)" (page 71)
.
Table 14
Media Gateway tone and Conference configuration (LD 17)
Prompt
Response
Description
REQ
CHG
TYPE
CFN
Configuration record.
CEQU
YES
Common equipment.
...
MGTDS
aaa bbb
Allows the configuration of two Media Gateway TDS
loops simultaneously.
aaa = loop, bbb = 0–255, X to delete the loop
IPMG
supl sh
Superloop and shelf of IPMG on which this MGTDS are
associated. No default value is assigned if the IPMG is
not associated. This prompt allows for the association
of the MGTDS with a particular IPMG.
supl = IPMG superloop, sh = IPMG shelf
MGCONF
aaa bbb ccc ddd
Allow the configuration of up to four Media Gateway
conference loops simultaneously.
aaa = loop, bbb = 0–255, X to delete the loop
IPMG
supl sh
Superloop and shelf of IPMG on which this MGTDS are
associated. No default value is assigned if IPMG is not
associated. This prompt allows for the association of
the MGTDS with a particular IPMG.
supl = IPMG superloop, sh = IPMG shelf
--End--
Configure the Media Gateway Controller
The MGC command line can be accessed using the NTBK48AA three-port
SDI cable. A null modem adapter is used to connect to the MGC serial
port.
Nortel Communication Server 1000
Media Gateway 1000E PRI Gateway Installation and Commissioning
NN43041-311 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.
Содержание 1000E PRI
Страница 161: ......