Media Gateway Controller system alarms, events, and messages
Message
Severity
Description
Corrective action
Output
(TTY, LOG,
SNMP, LED)
MGC0004
Major
MGC <supl shelf> unable
to process the upgrade
request from the Call
Server.
Contact Nortel support.
TTY, LOG,
SNMP
MGC0005
Major
MGC <supl shelf> unable
to upgrade loadware
<loadware version>.
Contact Nortel support.
TTY, LOG,
SNMP
MGC0006
Major
MGC <supl shelf> unable
to download loadware
<loadware version> from
the Call Server.
Check IP configuration
and network
connections. Confirm
the loadware exists
in the appropriate
directory on the Call
Server.
TTY, LOG,
SNMP
MGC0007
Major
MGC <supl shelf> unable
to synchronize passwords
from the Call Server.
Check IP configuration
and network
connections. Confirm
the password file exists
in the appropriate
directory on the Call
Server.
TTY, LOG,
SNMP
MGC0008
Major
MGC <supl shelf>
detected a problem
with loadware <loadware
version>, reverting to the
Gold image.
Contact Nortel Support.
TTY, LOG,
SNMP
MGC0011
(E003)
Critical
MGC <supl shelf> - Link
down to the Call Server.
Check IP configuration
and network
connections.
TTY, LOG,
SNMP
MGC0012
Clear
(E003)
MGC <supl shelf> - Link
down to the Call Server.
None
TTY, LOG,
SNMP
MGC0013
Info
MGC <supl shelf> -
Physical/link layer problem
detected, port <port
name>, <error code or
description?>
Check IP configuration
and network
connections.
TTY, LOG,
SNMP
MGC0014
Info
MGC <supl shelf> - User
<LDS1/LDS2> has logged
into the card.
None
TTY, LOG,
SNMP
Nortel Communication Server 1000