Configure E1/T1 ports on a Call Server
85
•
CE-MUX clock controllers
•
PRI, PRI2, and DPNSS/DASS routes
•
PRI, PRI2, and DPNSS/DASS trunks
PRI digital trunk loop configuration
Procedure 16 “Configuring PRI loops using LD 17” (page 85)
describes
the configuration in LD 17 to support PRI/T1 loops (common equipment
parameters) on the PRI Gateway.
Procedure 16
Configuring PRI loops using LD 17
Step
Action
1
Log on to the CS 1000E.
2
To access LD 17, enter:
LD 17
3
Enter the responses shown in
Table 16 "PRI loop configuration
ATTENTION
VDC configuration is not required for DASS signaling.
Table 16
PRI loop configuration (LD 17)
Prompt
Response
Description
REQ
CHG
Change existing data.
TYPE
CEQU
Make changes to common equipment parameters.
CFN
YES
Common equipment.
...
DLOP
loop dd ff
Digital loop (1.5 Mb)
The format is: loop is 0–254, dd is 0-24 (maximum
simultaneous calls) and ff is D2, D3, D4, or ESF.
Enter X to delete the loop.
MG_CARD
supl sh card
The physical card for the digital loop association to the
PRI Gateway is required.
The format is: superloop, shelf num, card num. For the
PRI Gateway, card 1-8 is applicable.
MODE
PRI
Mode of operation.
TMDI
NO
TMDI functionality is not supported for MGP gateway.
...
...
Nortel Communication Server 1000
Media Gateway 1000E PRI Gateway Installation and Commissioning
NN43041-311 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.