Initial configuration of the E1/T1 card
107
4
Verify the network connections. For detailed information, see
“Verify network connections” (page 110)
.
--End--
Power up the system
When you first install and power up the PRI Gateway, the E1/T1 banner
appears on the window. See
Figure 21 "General status display" (page
which displays an example of three enabled spans. After the first
power-up, the banner parameters are empty.
The window displays the following information:
•
logo
•
customer-defined card name
•
status of the E1/T1 spans
•
IP address
The window displays one line for each E1/T1 span.
The Protocol column displays:
•
E1
•
T1
•
not defined
The Usage column displays what hardware is used for D-channel:
•
DDCH
•
DCHI
•
DCHI-SW
•
BCH (for BCH, no DCH hardware is needed)
The ClockReference column displays which span is the primary and
secondary reference clock. The Clock Controller track on field displays
on which span it is synchronized:
•
primary
•
secondary
•
free run
The Status displays the span status: either enabled or disabled.
Nortel Communication Server 1000
Media Gateway 1000E PRI Gateway Installation and Commissioning
NN43041-311 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.