SW4
-91A1
SW3
Fig. 3‐10
DIP switch
Installation
3‐10
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Key-to-line: Selecting Line Speed Voltage or Line
Speed Current on I/O Board
ATTENTION:
The melter must be switched off.
CAUTION:
Electrostatic charges can destroy electronic components. Wear
a grounding strap!
The DIP switch SW 3 on the I/O board can be used to choose between two
current ranges (0 to 20 mA and 4 to 20 mA). The DIP switch SW 4 on the I/O
board is used to switch between voltage and current.
The following tables indicate the original state when delivered by Nordson
(
).
NOTE:
If the line speed signal is a frequency, these DIP switch settings have
no relevance.
SW3
1
ON
4 - 20 mA
OFF
0 - 20 mA
2‐4
ON
OFF
-
One line speed signal
input for all motors
Separate line
speed signal
inputs (option)
SW4
1
ON
Current
-
OFF
Voltage (0-10 V)
2‐4
ON
-
-
OFF
NOTE:
Voltage
or
current
must also be set on the melter control panel.
Also refer to section
Operation
,
M2.1: Line Speed Signal
.
Содержание VersaBlue VA
Страница 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...