Actual
Kd
(differential
component)
PID pressure control
parameters
Kp (gain)
Ti (integral
action time)
PID effective
rate
%
ms
bar
Operation
4‐77
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Motor
(contd.)
PID pressure
control
t
PID Pressure Control Parameters
NOTE:
Should be adjusted only by personnel with experience in metrology
and control technology.
The regulation ratio is multiplied by the
Effective rate
.
Kp:
0.80
Ti:
600 ms
Kd:
0.0
Effective rate:
100.0 %