Automatic enter standby
after motor stop
60
min
Not
enabled
60
min Enabled
Manual standby duration
V9
Operation
4‐48
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Melter
(contd.)
Standby
Standby serves to protect the hot melt material and to save energy during
breaks in production.
For information on setting the standby value (value by which the setpoint
temperature is reduced), refer to
Control Panel - Overview - / T2.
Automatic Entry
Standby is entered as soon as all of the motors have been stopped for a
certain time. Enable
Automatic enter standby
for this purpose.
Manual Exit
Automatic standby is exited by the operator on the control panel
.
Manual standby duration
is ineffective here.
Automatic enter standby after motor stop:
Not enabled
(
60 min
if
enabled)
Manual Entry/Exit (Control Panel)
External Entry/Exit (Interface)
Either the operator enters and exits standby on the control panel
or this
occurs via the interface
Standard I/O
.
Automatic Exit
Exit standby can also occur automatically. Enable
Manual standby duration
for this purpose. After the set time has expired, the melter automatically
returns to heatup guided by reference channel.
Manual standby duration:
Not enabled
(
60 min
if enabled)
Entering/Exiting via the Seven-day Clock
Refer to
Control Panel - Overview - / V7
and
V8
.
Содержание VersaBlue VA
Страница 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...