Technical Data
9‐2
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Temperatures
CAUTION:
The maximum operating temperature of the installed gun and the
other heated components should be considered when setting temperatures
on the melter control panel.
Min. operating temperature
(setpoint)
40 °C
100 °
F
Max. operating
temperatures for standard
melters
Ni120 temperature sensor
230 °C
450
°
F
Pt 100
Ni120
Hose connections
Max. operating
temperatures for high
temperature melters
Pt100 temperature sensor
250 °C
480 °
F
Overtemperature shutdown
by thermostat
260 °C
288 °C
500 °
F
550 °
F
Standard melter
High‐temperature melter
Shutdown by transformer
thermostat
155 °C
(± 5 °C)
311 °
F
(±9 °
F)
Max. operating temperature
of filling valve (option)
230 °C
450
°
F
Electrical Data
ATTENTION:
The unit is designed for only one operating voltage. Operate
only at the operating voltage shown on the ID plate.
Available operating
voltages
200 V
AC
3‐phase without neutral (
- Delta
)
230 V
AC
3‐phase without neutral (
- Delta
)
400 V
AC
3-phase with neutral (star
- WYE
)
400 V
AC
3‐phase without neutral (
- Delta
)
480 V
AC
3‐phase without neutral (
- Delta
)
Only with V12:
230 V
AC
1‐phase with neutral
Permissible voltage
deviations
Power supply:
Standard I/O:
± 10%
± 10%
Operating voltage
frequency
50/60 Hz
SCCR*
10 kA
Melter fuse protection
Refer to ID plate
Key‐to‐line
Max. input
0 to 10 V
DC
0 to 20 mA
4 to 20 mA
0 to 100 kHz
*
SCCR isthe abbreviation for:
Short Circuit Current Rating.
Содержание VersaBlue VA
Страница 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...