Troubleshooting
6‐27
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
LEDs of 5‐point Sensor Evaluator
6
5
4
3
2
1
7
8
16
LED
Fault or mode
Sensor cable color
1
Yellow
On
Material covering 1st measuring point
Tank empty
White (wh)
2
Yellow
On
Material covering 2nd measuring point
Tank level
low
Red (rd)
3
Yellow
On
Material covering 3rd measuring point
Start filling
Blue (bl)
4
Yellow
On
Material covering 4th measuring point
Stop filling
Green (gn)
5
Yellow
On
Material covering 5th measuring point
Tank
overfilled
Black (bk)
6
Green
Power
On
Supply voltage present
-
7
Red
Fault LED 2
On
Same as the fault indication
Level sensor defective
Switching sequence mixed up. Sensor cables
exchanged. Observe colors!
-
8
Red
Fault LED 1
Same as the fault indication
Level sensor failure
-
On
Broken wire at highest or lowest measuring point
-
Flashing
Broken wire at highest and lowest measuring point
or
Operating ground
BE
(16, Fig. 6‐3) connection
interrupted
-
Содержание VersaBlue VA
Страница 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...