Operation
4‐82
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Setting up Connection Between the Server and the Client
ATTENTION:
Switch off the melter with the main switch and disconnect
from the line voltage.
1. Fig. 4‐112 shows the area on the back of the melter intended to
accommodate the cable.
Punch out perforated plate and remove.
2. Connect the EtherNet cable.
NOTE:
This EtherNet cable is not used to transfer data on the field bus,
described in the separate field bus document, section
EtherNet/IP
.
Connecting EtherNet Cable
6
3
4
2
1
5
4
7
1. Release clamps (4) (if present) and pull the socket casing (2) off of the
casing plate (5).
2. Screw the casing plate (5) onto the back of the melter.
3. Release screws (3) and open socket casing.
4. Slide one of the sealing rings (1) onto the EtherNet cable (6).
5. Guide the cable through the socket casing, then insert the cable and
sealing ring in the socket casing and secure with a cable clamp.
Continued ...
Содержание VersaBlue VA
Страница 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Страница 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...