1
2
Maintenance
5-19
P/N 7146386A
E
2008 Nordson Corporation
VBN w/o Control System
Pressure Sensor
Available only with options
Pressure display
and
Pressure control.
WARNING:
System and material pressurized. Relieve pressure. Failure to
observe may result in serious burns.
Cleaning Separating Membrane
WARNING:
Hot! Risk of burns. Wear appropriate protective
clothing/equipment.
CAUTION:
Clean the separating membrane (Fig. 5-21) with particular care.
Never use hard tools.
Whenever possible, remove material residue only with a cleaning agent
recommended by the material supplier. Thermoplastic substances such as
hot melt adhesive may need to be heated with a hot air fan and then
carefully wiped off with a soft cloth.
Fig. 5-21
Screwing in Pressure Sensor
NOTE:
The melter part and the pressure sensor should be at room
temperature or at nearly the same temperature before the pressure sensor
is screwed in firmly.
1. Apply high temperature grease to the thread (Refer to
Processing
Materials
).
2. Screw the pressure sensor only into a very clean hole.
NOTE:
Do not tilt or jam when screwing into place.
Refer to Fig. 5-22: Top illustration wrong; bottom correct: The screw plug (2)
is used as a guide for the separating membrane (1).
Recommended installation torque: 13.6 Nm / 120 lbin
Max. installation torque permitted: 56 Nm / 500 lbin
Fig. 5-22
Top wrong
−
bottom right
CAUTION:
If the material hole is to be cleaned with a hard object, the
pressure sensor must first be removed; otherwise the separating membrane
would be damaged.
Fig. 5-23
Principle drawing
Содержание VersaBlue 100H/100H
Страница 46: ...Installation 3 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Страница 74: ...Maintenance 5 24 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Страница 94: ...Repair 7 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Страница 96: ...Parts 8 2 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...