55
80
10
Filling
Stop
at
Start
at
Low level
warning
Level
%
10
25 mm
max1
Operation
4-2
P/N 7146386A
E
2008 Nordson Corporation
VBN w/o Control System
Level Display and Control (Options)
Perform calibration. Refer to section
Repair
/
Replacing Level Evaluator
(Option) / Calibration
.
As soon as the material is changed, the level parameters must be adapted
to the new material on the control panel.
Fig. 4-2
Automatic Tank Filling
Automatic tank filling is performed e.g. by a bulk melter connected to the
optional filling valve with a hose. Level sensors in the tank start and stop the
filling process.
Fig. 4-3
Filling valve
Maximum Level
The level should not exceed 25 mm (1 inch) under the rim of the
tank
(max1).
Adapt the maximum level to the adhesive dispensing speed. Feed
adhesives sensitive to temperature quickly to prevent loss of quality.
Fig. 4-4
Cross-section of
tank
Содержание VersaBlue 100H/100H
Страница 46: ...Installation 3 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Страница 74: ...Maintenance 5 24 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Страница 94: ...Repair 7 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Страница 96: ...Parts 8 2 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...